Difference between revisions of "SiRad Easy 300 GHz Front End Board"

From indie Semiconductor Wiki
Jump to navigation Jump to search
(Return to Operation with automatic recognition of Radar Front Ends)
 
(28 intermediate revisions by 4 users not shown)
Line 1: Line 1:
 
__NUMBEREDHEADINGS__
 
__NUMBEREDHEADINGS__
 +
__TOC__
 +
<!--
 +
== EvalKit Easy – Operation with Front End TRA_300_030/042 in wide-band mode ==
 +
-->
  
== '''EvalKit Easy – Operation with Front End TRA_300_030 in wide-band modus''' ==
+
Please flash 300 GHz Front End firmware to Evalkit before following the steps below. You can download the firmware in our [https://login.siliconradar.com/ Customer Download Area] (you have to register at our site).
  
Since the EvalKit Easy is not recognizing radar front ends with wide band-operation capability a manual adaptation may become necessary.
+
== Power Connection ==
  
 +
=== Method 1 ===
  
 +
For the power supply to the front end, a separate connection is required. Figure 1 shows where to connect the power on the front end (marked in black: +5V and GND). Figure 2, shows the Easy kit with the front end mounted and connected. Figure 3 shows where to connect the power to the bottom side of the Easy: pin 18 (5V) and pin 20 (GND) of the CN7 connector on the Nucleo board. <b>Please be aware that the 5V pin of the header bar on the Easy cannot be used to power the front end!</b> Alternatively an external power source can be used. The supply current for the front end is 270mA (typical value).
  
== Cable Connection ==
+
{|
 +
|[[File:Evaluation-EvalKits-TRA 300 030.jpg|thumb|200px|Figure 1: Power connection (5V, GND) on the 300 GHz front end|link={{filepath:{{PAGENAME:Media:Evaluation-EvalKits-TRA 300 030.jpg}}}}]]
 +
|-
 +
|[[File:Fig1_EvalKit_Easy_FE300G.png|thumb|200px|Figure 2: EvalKit Easy with 300 GHz Front End mounted|link={{filepath:{{PAGENAME:Media:Fig1_EvalKit_Easy_FE300G.png}}}}]]
 +
|-
 +
||[[File:Evaluation Evalkits TRA 300 030 Power.jpg|thumb|200px|Figure 3: Power connection (5V, GND) on the bottom side of the Easy: pin 18 (5V) and pin 20 (GND) of the CN7 connector on the Nucleo board |link={{filepath:{{PAGENAME:Media:Evaluation Evalkits TRA 300 030 Power.jpg}}}}]]
 +
|}
  
 +
=== Method 2 ===
  
For the power supply to the front end a separate connection is required. The red power cable connects the 5V pin of the Front End board as shown in Fig. 1 with the pin E5V of the Easy board.
+
The front end can be also powered by an external +5V power source. For that, disconnect the Easy from the USB. Connect 5V and GND of the front end to +5V and GND of your power source, but do not power it on yet. Connect the USB again to the Easy kit. Now switch on the power of the external power source.
  
[[File:Fig1_EvalKit_Easy_FE300G.png|frameless]]
+
=== Method 3 ===
  
Fig. 1: EvalKit Easy with 300GHz Front End
+
Alternatively, the GND of the front end can be connected to one of the corner connectors (CN11 or CN12) of the Nucleo and the 5V of the front end can be connected to the U5V connector of the Nucleo.
  
 
== Software Start ==
 
== Software Start ==
  
 +
To launch the software evaluation platform please follow the routine described below:
  
To launch the software evaluation platform please follow this routine:
+
*open and connect the WebGUI
 +
*press the black reset button on the Easy Board (see Figure 2)
  
- connect the WebGUI
+
In the best case, you already have some useful output if you are pointing the radar head towards a defined target, e.g. the ceiling. In the example shown in Figure 4, this obstacle/object has a distance of around 2m, an additional peak next to the DC peak (left limit of the diagram) can be caused by the operator. This situation describes the measurement result as it should look.
  
- press the black reset button on the Easy Board (cf. Fig. 1)
+
{|
 +
|[[File:Fig2 GUIspecimen.png|thumb|200px|Figure 4: Graph of a radar measurement with one obstacle in 2m distance as it should look like |link={{filepath:{{PAGENAME:Media:Fig2 GUIspecimen.png}}}}]]
 +
|}
  
In the best case you already have some useful output if you are pointing the radar head towards a defined target, e.g. the ceiling. In the example shown in Fig. 2 this obstacle/object has a distance of around 2m, an additional peak next to the DC peak (left limit of the diagram) can be caused by the operator. This situation describes the measurement result as it should look like.
+
However, you may end up with a measurement graph rather similar to the one shown in Figure 5.
  
[[File:Fig2 GUIspecimen.png|frameless]]
+
{|
 +
|[[File:Fig3_GUI_false_chart.png|thumb|200px|Figure 5: Resulting graph of a radar measurement, if operation conditions are not properly chosen |link={{filepath:{{PAGENAME:Media:Fig3_GUI_false_chart.png}}}}]]
 +
|}
  
Fig. 2: Graph of a radar measurement with one obstacle in 2m distance as it should look like [click to enlarge].
+
In such cases, the radar board operation and parameter setting need to be reviewed as described in Section 4. 
 
 
 
 
But maybe you may end up with a measurement graph rather similar to the one shown in Fig. 3.
 
 
 
[[File:Fig3_GUI_false_chart.png|frameless]]
 
 
Fig. 3: Resulting graph of a radar measurement, if operation conditions are not properly chosen [click to enlarge].
 
 
 
In such case the radar board operation and parameter setting needs to be reviewed as described in Section 4. 
 
  
 
== Parameter Setting ==
 
== Parameter Setting ==
 
   
 
   
 +
Without depending on the measurement graph you receive, please continue with the following steps:
  
Whatever measurement graph you receive, please continue with the following steps:
+
- RF Parameters tab
 +
  o Insert a Bandwidth (MHz) of 40'000 MHz
 +
  o Set the Base frequency (MHz) to 289'000 MHz
  
- Go to RF Parameters tab (cf. Fig. 17 in the user guide)
+
- BB Processing tab
  o Leave the Selector Field "Front End" unchanged at 24, 60 or 122GHz, since it will not influence the further measurement.
 
  o Set the VCO devider to 128
 
  o Insert a Bandwidth (MHz) of 40'000 MHz as start value and increase later to the maximum bandwidth used
 
  o Set the Base frequency (MHz) to 289'000 MHz.
 
 
 
- Go to BB Processing tab
 
 
   o Adjust ADC clock divider to around 1-2ms or more (please watch the DC peaks)
 
   o Adjust ADC clock divider to around 1-2ms or more (please watch the DC peaks)
   o Adjust Number of samples to 1024 or more
+
   o Adjust the Number of samples to 1024 or more
 
   o Adjust FFT size to 1024
 
   o Adjust FFT size to 1024
  
 +
After you have performed all steps you should get an output similar to the one in Figure 6.
  
 
+
{|
After you have performed all steps you should get an output similar to the one in Fig. 4.
+
|[[File:Fig4_GUI_corrected_parameter.png|thumb|200px|Figure 6: Radar Measurement following the parameter setting, still targeting an object in a distance of 2 meters |link={{filepath:{{PAGENAME:Media:Fig4_GUI_corrected_parameter.png}}}}]]
 
+
|}
[[File:Fig4_GUI_corrected_parameter.png|frameless]]
 
 
Fig. 4: Radar Measurement following the parameter setting,  
 
still targeting an object in a distance of 2 meters [click to enlarge].
 
 
 
== Return to Operation with automatic recognition of Radar Front Ends ==
 
 
 
For operation of SiRad Easy radar front ends with automatic recognition exchange the front end boards as previously used and restart operation.
 

Latest revision as of 06:52, 16 June 2021

Please flash 300 GHz Front End firmware to Evalkit before following the steps below. You can download the firmware in our Customer Download Area (you have to register at our site).

1 Power Connection

1.1 Method 1

For the power supply to the front end, a separate connection is required. Figure 1 shows where to connect the power on the front end (marked in black: +5V and GND). Figure 2, shows the Easy kit with the front end mounted and connected. Figure 3 shows where to connect the power to the bottom side of the Easy: pin 18 (5V) and pin 20 (GND) of the CN7 connector on the Nucleo board. Please be aware that the 5V pin of the header bar on the Easy cannot be used to power the front end! Alternatively an external power source can be used. The supply current for the front end is 270mA (typical value).

Figure 1: Power connection (5V, GND) on the 300 GHz front end
Figure 2: EvalKit Easy with 300 GHz Front End mounted
Figure 3: Power connection (5V, GND) on the bottom side of the Easy: pin 18 (5V) and pin 20 (GND) of the CN7 connector on the Nucleo board

1.2 Method 2

The front end can be also powered by an external +5V power source. For that, disconnect the Easy from the USB. Connect 5V and GND of the front end to +5V and GND of your power source, but do not power it on yet. Connect the USB again to the Easy kit. Now switch on the power of the external power source.

1.3 Method 3

Alternatively, the GND of the front end can be connected to one of the corner connectors (CN11 or CN12) of the Nucleo and the 5V of the front end can be connected to the U5V connector of the Nucleo.

2 Software Start

To launch the software evaluation platform please follow the routine described below:

  • open and connect the WebGUI
  • press the black reset button on the Easy Board (see Figure 2)

In the best case, you already have some useful output if you are pointing the radar head towards a defined target, e.g. the ceiling. In the example shown in Figure 4, this obstacle/object has a distance of around 2m, an additional peak next to the DC peak (left limit of the diagram) can be caused by the operator. This situation describes the measurement result as it should look.

Figure 4: Graph of a radar measurement with one obstacle in 2m distance as it should look like

However, you may end up with a measurement graph rather similar to the one shown in Figure 5.

Figure 5: Resulting graph of a radar measurement, if operation conditions are not properly chosen

In such cases, the radar board operation and parameter setting need to be reviewed as described in Section 4. 

3 Parameter Setting

Without depending on the measurement graph you receive, please continue with the following steps:

- RF Parameters tab

 o	Insert a Bandwidth (MHz) of 40'000 MHz
 o	Set the Base frequency (MHz) to 289'000 MHz

- BB Processing tab

 o	Adjust ADC clock divider to around 1-2ms or more (please watch the DC peaks)
 o	Adjust the Number of samples to 1024 or more
 o	Adjust FFT size to 1024

After you have performed all steps you should get an output similar to the one in Figure 6.

Figure 6: Radar Measurement following the parameter setting, still targeting an object in a distance of 2 meters